Part 1 Specification

Chapter 3 Gateway R unit

143

Part 1 Specification

‹

Start Command (CSTR)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

06 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

0B H

2

Address of the control signal register of axis (0)

New data (data written) (upper)

00 H

New data (data written) (lower)

11 H

2

The SON and CSTR signals are “1.”

Error check

(CRC)

16 bits

2

Based on calculation result

Trailer

None

-

Total bytes

8

z

Response

If the data has been changed (written) successfully, the response is the same as the query.

z

Actual Example

„

Sent Query:

3F06F60B00110F52

„

Received Response: 3F06F60B00110F52

[Function]

Upon detection of the signal edge for executing the position command when the new data is in normal state, the content

of the position number register will be read and positioning will be performed to the target position of the corresponding

position data.

If the position start command for the new data remains ON, the position complete signal (PEND) will not be output even

when the actuator enters the positioning band. However, the completed position number signal (PM***) will be output.

If this command is executed when no home return operation has been performed after the power on (when HEND = “0”),

the actuator will perform home return operation and then start moving to the target position.

-167-