Part 1 specification – IAI America REXT User Manual

Page 39

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

23

Part 1 Specification

Item

Specification

Power supply

24 VDC r 10%

Current consumption

600 mA max.

Communication protocol

CC-Link Version 2.00 (Version 1.10)

Baud rate

10

M/5M/2.5M/625k/156k [bps] (Set by a ROBONET gateway parameter)

Communication method

Broadcast polling method

Synchronization method

Frame synchronization method

Encoding method

NRZI

Transmission path type

Bus type (Conforming to EIA RS485)

Transmission format

Conforming to HDLC

Error control method

CRC (X

16

+ X

12

+ X

5

+ 1)

Number of occupiable stations

Remote device stations: four x1 stations, two x4 stations or two x8 stations

Baud rate (bps)

10M

5M

2.5M

625k

156k

Communication cable length (*1)

Total cable length (m)

100

160

400

900

1200

C

C

-L

in

k

sp

ec

ifi

ca

tio

n

Communication cable

Dedicated CC-Link cable

Transmission path configuration IAI’s dedicated multi-drop differential communication

Communication method

Half-duplex

Synchronization method

Asynchronous method

Transmission path type

2-wire method corresponding to EIA RS485

Baud rate

230.4k [bps]

Error control method

CRC with no parity bit (*2)

Communication cable

ROBONET communication connection circuit board (supplied), ROBONET

extension cable (when an extension unit is used)

S

IO

c

om

m

un

ic

at

io

n

sp

ec

ifi

ca

tio

n

Number of connectable units

16 axes max.

Ambient operating temperature 0 to 40qC

Ambient operating humidity

95% RH max. (non-condensing)

Operating ambience

Free from corrosive gases, flammable gases, oil mist or powder dust.

Storage temperature

-25 to 70qC

Storage humidity

95% RH max. (non-condensing)

Vibration resistance

XYZ directions:

10 to 57 Hz, half amplitude – 0.035 mm (continuous) / 0.075 mm (intermittent)

57 to 150 Hz – 4.9 m/s

2

(continuous) / 9.8 m/s

2

(intermittent)

E

nv

iro

nm

en

t

co

nd

iti

on

s

Impact resistance

XYZ directions: 147 mm/s

2

, 11 ms, half-sine wave pulse

Protection degree

IP20

Weight

Approx. 140 g

External dimensions

34 W x 105 H x 73.3 D [mm]

*1: For T-branching communication, refer to the operation manuals of the master unit and the PLC installed in the master unit.

*2: CRC: Cyclic Redundancy Check

A data error detection method frequently used for synchronous transmission.

-39-

Advertising
This manual is related to the following products: