Part 2 Startup Chapter

Chapter 5 Network Setup

329

Part 2 Startup Chapter

[c] Double-click the

CPU Unit Settings tab in the PLC System Settings dialog box, and set the necessary items

in the “Communication Command Settings in FB” area as follows:

x

Number of Resends:

Set the number of times the data will be resent if the PLC has experienced a

communication error while communicating with the gateway unit.

(Example) 5

x

Response Monitoring Time/Communication Commands in FB:

Response monitoring time per communication cycle.

Set this monitoring time to 5 seconds or longer.

[d] When the above items have been set, transfer the settings to the PLC.

Click

Options (O), and click Transfer [PC Æ PLC] (P).

When a dialog box appears and asks if you want to transfer the settings to the PLC, click

Yes.