Part 1 specification – IAI America REXT User Manual

Page 173

Advertising
background image



Part 1 Specification

Chapter 3 Gateway R unit

149

Part 1 Specification

‹

Jog- Command (JOG-)

z

Query

Field name

RTU mode data

(8 bits)

Data length

(bytes)

Remarks

Header

None

-

Slave address

3F H

1

Fixed.

Function code

06 H

1

Starting address

(upper)

F6 H

Starting address

(lower)

0B H

2

Address of the control signal register of axis (0)

New data (data written) (upper)

Arbitrary

New data (data written) (lower)

Arbitrary

2

Used in combination with the JISL and JVEL

signals.

Error check

(CRC)

16 bits

2

Based on calculation result

Trailer

None

-

Total bytes

8

z

Response

If the data has been changed (written) successfully, the response is the same as the query.

[Function] This signal is used to start jogging operation or inching operation.

„

Jogging Operation in - Direction

When the JOG- signal is turned “1” while the JISL signal is “0” (jogging mode), the actuator will jog in the direction

home. The speed corresponds to the jogging speed of the parameter specified by the JVEL signal, while the

acceleration/deceleration corresponds to the rated acceleration/deceleration (the specific value varies depending

on the actuator).

„

How to Stop Jogging Operation in - Direction

x

Change the JOG- signal from “1” to “0” during operation.

x

Change the JOG+ signal from “0” to “1” during operation.

„

Inching Operation

The actuator will inch in the direction home every time the JOG- signal changes from “0” to “1” while the JISL signal

is “1” (inching mode). The speed and travel distance correspond to the jogging speed and inching distance of the

parameters specified by the JVEL signal, while the acceleration/deceleration corresponds to the rated

acceleration/deceleration (the specific value varies depending on the actuator).

-173-

Advertising
This manual is related to the following products: