1.2.3 Examples of Indicator Statuses Corresponding to Representative Alarms

Examples of indicator statuses corresponding to representative alarms are shown for CC-Link and DeviceNet systems.

(1) CC-Link

z

: Lit {: Unlit ~: Blinking

Gateway unit

Master

ERROR-T

(Orange)

ERROR-C

(Orange)

STATUS-1

(Orange)

STATUS-0

(Orange)

ERR

(Red)

Operation/condition

{

{

{

z

{

Normal

{

{

{

{

z

The 24-V power supply of the gateway unit is turned off.

{

z

{

{

{

The power supply of the master is turned off.

{

z

{

{

The network cable is disconnected.

z

{

{

z

{

The ROBONET communication connection board is

detached.

{

z

{

{

z

The station number setting of the gateway unit is different

from the station number registered to the master.

{

z

{

{

z

The baud speed setting of the master is different from the

corresponding setting of the gateway unit.

z

z

{

z

{

The axis configuration (occupancy information) of the

gateway unit is different from the actual configuration.

{

{

{

z

~

The master network parameter for number of connected

units is different from the actual number of units.

{

z

{

{

z

The master network parameter for station type is wrong.

{

z

{

{

z

The master network parameter for number of occupied

station is wrong.

(2) DeviceNet

z

: Lit {: Unlit ~: Blinking

Gateway unit

Master

ERROR-T

(Orange)

ERROR-C

(Orange)

STATUS-1 STATUS-0

NS

Operation/condition

{

{

z

Green

z

Green

z

Green Normal

{

z

z

Green

z

Green

~

Red The 24-V power supply of the gateway unit is turned off.

{

z

~

Orange

z

Green

{

The power supply of the master is turned off.

{

z

{

z

Green

~

Red The network cable is disconnected.

z

{

z

Green

z

Green

z

Green The ROBONET communication connection board is

detached.

{

~

~

Green z Green

~

Red The station number setting of the gateway unit is different

from the station number registered to the master.

{

~

~

Green z Green

~

Red The axis configuration (occupancy information) of the

gateway unit is different from the actual configuration.

{

~

~

Green z Green

~

Red The I/O size setting in the master scan list is wrong.

{

z

~

Orange

z

Green

~

Red The station number setting (switch) of the master unit has

been changed after the network was set up.