LevelOne GTL-2691 User Manual

Page 1310

Advertising
background image

C

HAPTER

44

| CFM Commands

– 1310 –

ethernet cfm mep

Sets an interface as a domain boundary, defines it as

a maintenance end point (MEP), and sets direction of

the MEP in regard to sending and receiving CFM

messages

IC

ethernet cfm port-enable

Enables CFM processing on an interface

IC

clear ethernet cfm ais

mpid

Clears AIS defect information for the specified MEP

PE

show ethernet cfm

configuration

Displays CFM configuration settings, including global

settings, SNMP traps, and interface settings

PE

show ethernet cfm md

Displays configured maintenance domains

PE

show ethernet cfm ma

Displays configured maintenance associations

PE

show ethernet cfm

maintenance-points local

Displays maintenance points configured on this device PE

show ethernet cfm

maintenance-points local

detail mep

Displays detailed CFM information about a specified

local MEP in the continuity check database

PE

show ethernet cfm

maintenance-points

remote detail

Displays detailed CFM information about a specified

remote MEP in the continuity check database

PE

Continuity Check Operations

ethernet cfm cc ma

interval

Sets the transmission delay between continuity check

messages

GC

ethernet cfm cc enable

Enables transmission of continuity check messages

within a specified maintenance association

GC

snmp-server enable traps

ethernet cfm cc

Enables SNMP traps for CFM continuity check events

GC

mep archive-hold-time

Sets the time that data from a missing MEP is kept in

the continuity check database before being purged

CFM

clear ethernet cfm

maintenance-points

remote

Clears the contents of the continuity check database

PE

clear ethernet cfm errors

Clears continuity check errors logged for the specified

maintenance domain and maintenance level

PE

show ethernet cfm errors

Displays CFM continuity check errors logged on this

device

PE

Cross Check Operations

ethernet cfm mep

crosscheck start-delay

Sets the maximum delay that a device waits for

remote MEPs to come up before starting the cross-

check operation

GC

snmp-server enable traps

ethernet cfm crosscheck

Enables SNMP traps for CFM continuity check events,

in relation to the cross-check operations between

statically configured MEPs and those learned via

continuity check messages

GC

mep crosscheck mpid

Statically defines a remote MEP in a maintenance

association

CFM

ethernet cfm mep

crosscheck

Enables cross-checking between the list of configured

remote MEPs within a maintenance association and

MEPs learned through continuity check messages

PE

show ethernet cfm

maintenance-points

remote crosscheck

Displays information about remote maintenance

points configured statically in a cross-check list

PE

Table 169: CFM Commands (Continued)

Command

Function

Mode

Advertising