Table 175: remote mep priority levels, Table 176: mep defect descriptions – LevelOne GTL-2691 User Manual

Page 1346

Advertising
background image

C

HAPTER

44

| CFM Commands

Fault Generator Operations

– 1346 –

notification generator state machine has been reset, and repeat those

steps until the fault is resolved.

Only the highest priority defect currently detected is reported in the

fault alarm.

Priority defects include the following items:

E

XAMPLE

This example sets the lowest priority defect that will generate a fault

alarm.

Console(config)#ethernet cfm domain index 1 name voip level 3

Console(config-ether-cfm)#mep fault-notify lowest-priority 1

Console(config-ether-cfm)#

Table 175: Remote MEP Priority Levels

Priority Level

Level Name

Description

1

allDef

All defects.

2

macRemErrXcon

DefMACstatus, DefRemoteCCM, DefErrorCCM, or

DefXconCCM.

3

remErrXcon

DefErrorCCM, DefXconCCM or DefRemoteCCM.

4

errXcon

DefErrorCCM or DefXconCCM.

5

xcon

DefXconCCM

6

noXcon

No defects DefXconCCM or lower are to be

reported.

Table 176: MEP Defect Descriptions

Field

Description

DefMACstatus

Either some remote MEP is reporting its Interface Status TLV as

not isUp, or all remote MEPs are reporting a Port Status TLV that

contains some value other than psUp.

DefRemoteCCM

The MEP is not receiving valid CCMs from at least one of the

remote MEPs.

DefErrorCCM

The MEP has received at least one invalid CCM whose CCM

Interval has not yet timed out.

DefXconCCM

The MEP has received at least one CCM from either another MAID

or a lower MD Level whose CCM Interval has not yet timed out.

Advertising