Connectivity Fault Management

– 508 –

EgrVid – The Egress Port can be identified, but the bridge port is not

in the LTM’s VID member set, and was therefore filtered by egress

filtering.

Reply – Reply action:

FDB – Target address found in forwarding database.

MPDB – Target address found in the maintenance point database.

HIT – Target located on this device.

W

EB

I

NTERFACE

To show information about link trace operations launched from this device:

1.

Click Administration, CFM.

2.

Select Show Information from the Step list.

3.

Select Show Link Trace Cache from the Action list.

Figure 286: Showing the Link Trace Cache

D

ISPLAYING

F

AULT

N

OTIFICATION

S

ETTINGS

Use the Administration > CFM > Show Information (Show Fault Notification

Generator) page to display configuration settings for the fault notification

generator.

CLI R

EFERENCES

"show ethernet cfm fault-notify-generator" on page 1347

P

ARAMETERS

These parameters are displayed:

MEP ID – Maintenance end point identifier.

MD Name – Maintenance domain name.

MA Name – Maintenance association name.

Highest Defect – The highest defect that will generate a fault alarm.

(This is disabled by default.)

Lowest Alarm – The lowest defect that will generate a fault alarm