Show ethernet cfm errors – LevelOne GTL-2691 User Manual

Page 1334

Advertising
background image

C

HAPTER

44

| CFM Commands

Continuity Check Operations

– 1334 –

show ethernet cfm

errors

This command displays the CFM continuity check errors logged on this

device.

S

YNTAX

show ethernet cfm errors [domain domain-name | level level-id]

domain-name – Domain name. (Range: 1-43 alphanumeric

characters)
level-id – Authorized maintenance level for this domain.

(Range: 0-7)

D

EFAULT

S

ETTING

None

C

OMMAND

M

ODE

Privileged Exec

E

XAMPLE

Console#show ethernet cfm errors

Level VLAN MPID Interface Remote MAC Reason MA Name

----- ---- ---- --------- ----------------- ---------------- ----------------

5 2 40 Eth 1/1 ab.2f.9c.00.05.01 LEAK provider_1_2

Console#

Table 173: show ethernet cfm errors - display description

Field

Description

Level

Maintenance level associated with this entry.

VLAN

VLAN in which this error occurred.

MPID

Identifier of remote MEP.

Interface

Port at which the error was recorded

Remote MAC

MAC address of remote MEP.

Reason

Error types include:
LEAK – MA x is associated with a specific VID list

*

, one or more of

the VIDs in this MA can pass through the bridge port, no MEP is

configured facing outward (down) on any bridge port for this MA,

and some other MA y, at a higher maintenance level, and associated

with at least one of the VID(s) also in MA x, does have a MEP

configured on the bridge port.
VIDS – MA x is associated with a specific VID list

*

on this MA on the

bridge port, and some other MA y, associated with at least one of the

VID(s) also in MA x, also has an Up MEP configured facing inward

(up) on some bridge port.
EXCESS_LEV – The number of different MD levels at which MIPs are

to be created on this port exceeds the bridge's capabilities.
OVERLAP_LEV – A MEP is created for one VID at one maintenance

level, but a MEP is configured on another VID at an equivalent or

higher level, exceeding the bridge's capabilities.

* This definition is based on the IEEE 802.1ag standard. Current software for this switch

only supports a single VLAN per MA. However, since it may interact with other devices
which support multiple VLAN assignments per MA, this error message may be
reported.