Troubleshooting, Problems accessing the management interface, Roubleshooting – LevelOne GTL-2691 User Manual

Page 1607: Table 239: troubleshooting chart, Roblems, Ccessing, Anagement, Nterface

Advertising
background image

– 1607 –

B

T

ROUBLESHOOTING

P

ROBLEMS

A

CCESSING

THE

M

ANAGEMENT

I

NTERFACE

Table 239: Troubleshooting Chart

Symptom

Action

Cannot connect using

Telnet, web browser, or

SNMP software

◆

Be sure the switch is powered up.

◆

Check network cabling between the management station and

the switch.

◆

Check that you have a valid network connection to the switch

and that the port you are using has not been disabled.

◆

Be sure you have configured the VLAN interface through which

the management station is connected with a valid IP address,

subnet mask and default gateway.

◆

Be sure the management station has an IP address in the same

subnet as the switch’s IP interface to which it is connected.

◆

If you are trying to connect to the switch via the IP address for

a tagged VLAN group, your management station, and the ports

connecting intermediate switches in the network, must be

configured with the appropriate tag.

◆

If you cannot connect using Telnet, you may have exceeded the

maximum number of concurrent Telnet/SSH sessions

permitted. Try connecting again at a later time.

Cannot connect using

Secure Shell

◆

If you cannot connect using SSH, you may have exceeded the

maximum number of concurrent Telnet/SSH sessions

permitted. Try connecting again at a later time.

◆

Be sure the control parameters for the SSH server are properly

configured on the switch, and that the SSH client software is

properly configured on the management station.

◆

Be sure you have generated both an RSA and DSA public key

on the switch, exported this key to the SSH client, and enabled

SSH service.

◆

Be sure you have set up an account on the switch for each SSH

user, including user name, authentication level, and password.

◆

Be sure you have imported the client’s public key to the switch

(if public key authentication is used).

Cannot access the on-

board configuration

program via a serial port

connection

◆

Be sure you have set the terminal emulator program to VT100

compatible, 8 data bits, 1 stop bit, no parity, and the baud rate

set to 115200 bps.

◆

Check that the null-modem serial cable conforms to the pin-out

connections provided in the Installation Guide.

Forgot or lost the

password

◆

Contact your local distributor.