– 860 –

sflow timeout

This command configures the length of time samples are sent to the

Collector before resetting all sFlow port parameters. Use the no form to

restore the default time out.

S

YNTAX

sflow timeout seconds
no sflow timeout

seconds - The length of time the sFlow process continuously sends

samples to the Collector before resetting all sFlow port parameters.

(Range: 0-10000000 seconds, where 0 indicates no time out)

D

EFAULT

S

ETTING

Disabled

C

OMMAND

M

ODE

Interface Configuration (Ethernet)

C

OMMAND

U

SAGE

The sFlow parameters affected by this command include the sampling

interval, the receiver’s name, address and UDP port, the time out,

maximum header size, and maximum datagram size.

E

XAMPLE

This example sets the time out to 1000 seconds.

Console(config)#interface ethernet 1/9

Console(config-if)#sflow timeout 10000

Console(config-if)#

show sflow

This command shows the global and interface settings for the sFlow

process.

S

YNTAX

show sflow interface [interface]

interface

ethernet unit/port

unit - Stack unit. (Range: 1-8)
port - Port number. (Range: 1-26)