Figure 217: configuring lldp timing attributes – LevelOne GTL-2691 User Manual

Page 412

Advertising
background image

C

HAPTER

14

| Basic Administration Protocols

Link Layer Discovery Protocol

– 412 –

should therefore periodically check the value of

lldpStatsRemTableLastChangeTime to detect any lldpRemTablesChange

notification-events missed due to throttling or transmission loss.

MED Fast Start Count – Configures the amount of LLDP MED Fast

Start LLDPDUs to transmit during the activation process of the LLDP-

MED Fast Start mechanism. (Range: 1-10 packets; Default: 4 packets)
The MED Fast Start Count parameter is part of the timer which ensures

that the LLDP-MED Fast Start mechanism is active for the port. LLDP-

MED Fast Start is critical to the timely startup of LLDP, and therefore

integral to the rapid availability of Emergency Call Service.

W

EB

I

NTERFACE

To configure LLDP timing attributes:

1.

Click Administration, LLDP.

2.

Select Configure Global from the Step list.

3.

Enable LLDP, and modify any of the timing parameters as required.

4.

Click Apply.

Figure 217: Configuring LLDP Timing Attributes