Stopbits, Timeout login response, Stopbits 796 timeout login response – LevelOne GTL-2691 User Manual

Page 796

Advertising
background image

C

HAPTER

24

| System Management Commands

Line

– 796 –

stopbits

This command sets the number of the stop bits transmitted per byte. Use

the no form to restore the default setting.

S

YNTAX

stopbits {1 | 2}
no stopbits

1 - One stop bit
2 - Two stop bits

D

EFAULT

S

ETTING

1 stop bit

C

OMMAND

M

ODE

Line Configuration

E

XAMPLE

To specify 2 stop bits, enter this command:

Console(config-line)#stopbits 2

Console(config-line)#

timeout login

response

This command sets the interval that the system waits for a user to log into

the CLI. Use the no form to restore the default setting.

S

YNTAX

timeout login response [seconds]
no timeout login response

seconds - Integer that specifies the timeout interval.

(Range: 10 - 300 seconds; 0: disabled)

D

EFAULT

S

ETTING

300 seconds

C

OMMAND

M

ODE

Line Configuration

C

OMMAND

U

SAGE

If a login attempt is not detected within the timeout interval, the

connection is terminated for the session.

This command applies to both the local console and Telnet connections.

The timeout for Telnet cannot be disabled.

Using the command without specifying a timeout restores the default

setting.