Displaying details for local meps – LevelOne GTL-2691 User Manual

Page 501

Advertising
background image

C

HAPTER

14

| Basic Administration Protocols

Connectivity Fault Management

– 501 –

D

ISPLAYING

D

ETAILS

FOR

L

OCAL

MEP

S

Use the Administration > CFM > Show Information (Show Local MEP

Details) page to show detailed CFM information about a local MEP in the

continuity check database.

CLI R

EFERENCES

"show ethernet cfm maintenance-points local detail mep" on page 1326

P

ARAMETERS

These parameters are displayed:

MD Index – Domain index. (Range: 1-65535)

MA Index – MA identifier. (Range: 0-4094)

MEP ID – Maintenance end point identifier. (Range: 1-8191)

MD Name – The maintenance domain for this entry.

MA Name – Maintenance association to which this remote MEP

belongs.

MA Name Format – The format of the Maintenance Association name,

including primary VID, character string, unsigned Integer 16, or

RFC 2865 VPN ID.

Level – Maintenance level of the local maintenance point.

Direction – The direction in which the MEP faces on the Bridge port (up

or down).

Interface – The port to which this MEP is attached.

CC Status – Shows if the MEP will generate CCM messages.

MAC Address – MAC address of the local maintenance point. (If a CCM

for the specified remote MEP has never been received or the local MEP

record times out, the address will be set to the initial value of all Fs.)

Defect Condition – Shows the defect detected on the MEP.

Received RDI – Receive status of remote defect indication (RDI)

messages on the MEP.

AIS Status – Shows if MEPs within the specified MA are enabled to

send frames with AIS information following detection of defect

conditions.

AIS Period – The interval at which AIS information is sent.

AIS Transmit Level – The maintenance level at which AIS information

will be sent for the specified MEP.