LevelOne GTL-2691 User Manual

Page 173

Advertising
background image

C

HAPTER

5

| Interface Configuration

Port Configuration

– 173 –

The test takes approximately 5 seconds. The switch displays the results

of the test immediately upon completion, including common cable

failures, as well as the status and approximate length to a fault.

Potential conditions which may be listed by the diagnostics include:

OK: Correctly terminated pair

Open: Open pair, no link partner

Short: Shorted pair

Not Supported: This message is displayed for any Gigabit Ethernet

ports linked up at a speed lower than 1000 Mbps, or for any 10G

Ethernet ports.

Impedance mismatch: Terminating impedance is not in the

reference range.

Ports are linked down while running cable diagnostics.

P

ARAMETERS

These parameters are displayed:

Port – Switch port identifier. (Range: 1-26)

Test Result – The results include common cable failures, as well as the

status and approximate distance to a fault, or the approximate cable

length if no fault is found.

Accuracy – The accuracy of the reported length to a fault.

(The accuracy displays “0” when no problem is found.)

Last Updated – Shows the last time this port was tested.

Action – Click Test to start cable test for selected port.