Show ethernet cfm maintenance-points remote detail, Show ethernet cfm, Maintenance-points – LevelOne GTL-2691 User Manual

Page 1327: Remote detail

Advertising
background image

C

HAPTER

44

| CFM Commands

Defining CFM Structures

– 1327 –

show ethernet cfm

maintenance-points

remote detail

This command displays detailed CFM information about a remote MEP in

the continuity check database.

S

YNTAX

show ethernet cfm maintenance-points remote detail

{mac mac-address | mpid mpid}

[domain domain-name | level level-id | ma ma-name]
mac-address – MAC address of a remote maintenance point.

This address can be entered in either of the following formats:

xx-xx-xx-xx-xx-xx or xxxxxxxxxxxx
mpid – Maintenance end point identifier. (Range: 1-8191)
domain-name – Domain name. (Range: 1-43 alphanumeric

characters)
level-id – Authorized maintenance level for this domain.

(Range: 0-7)

Table 171: show ethernet cfm maintenance-points local detail mep - display

Field

Description

MPID

MEP identifier

MD Name

The maintenance domain for this entry.

MA Name

Maintenance association to which this remote MEP belongs

MA Name Format

The format of the Maintenance Association name, including primary

VID, character string, unsigned Integer 16, or RFC 2865 VPN ID

Level

Maintenance level of the local maintenance point

Direction

The direction in which the MEP faces on the Bridge port (up or

down).

Interface

The port to which this MEP is attached.

CC Status

Shows if the MEP will generate CCM messages.

MAC Address

MAC address of the local maintenance point. (If a CCM for the

specified remote MEP has never been received or the local MEP

record times out, the address will be set to the initial value of all Fs.)

Defect Condition

Shows the defect detected on the MEP.

Received RDI

Receive status of remote defect indication (RDI) messages on the

MEP.

AIS Status

Shows if MEPs within the specified MA are enabled to send frames

with AIS information following detection of defect conditions.

AIS Period

The interval at which AIS information is sent.

AIS Transmit Level

The maintenance level at which AIS information will be sent for the

specified MEP.

Suppress Alarm

Shows if the specified MEP is configured to suppress sending frames

containing AIS information following the detection of defect

conditions.

Suppressing Alarms

Shows if the specified MEP is currently suppressing sending frames

containing AIS information following the detection of defect

conditions.