Ethernet cfm linktrace – LevelOne GTL-2691 User Manual

Page 1341

Advertising
background image

C

HAPTER

44

| CFM Commands

Link Trace Operations

– 1341 –

ethernet cfm

linktrace

This command sends CFM link trace messages to the MAC address of a

remote MEP.

S

YNTAX

ethernet cfm linktrace {dest-mep destination-mpid | src-mep

source-mpid {dest-mep destination-mpid | mac-address} |

mac-address} md domain-name ma ma-name [ttl number]
destination-mpid – The identifier of a remote MEP that is the target

of the link trace message. (Range: 1-8191)
source-mpid – The identifier of a source MEP that will send the link

trace message. (Range: 1-8191)
mac-address – MAC address of a remote MEP that is the target of

the link trace message. This address can be entered in either of the

following formats: xx-xx-xx-xx-xx-xx or xxxxxxxxxxxx
domain-name – Domain name. (Range: 1-43 alphanumeric

characters)
ma-name – Maintenance association name. (Range: 1-44

alphanumeric characters)
number – The time to live of the linktrace message. (Range: 0-255

hops)

D

EFAULT

S

ETTING

None

C

OMMAND

M

ODE

Privileged Exec

C

OMMAND

U

SAGE

Link trace messages can be targeted to MEPs, not MIPs. Before sending

a link trace message, be sure you have configured the target MEP for

the specified MA.

If the MAC address of target MEP has not been learned by any local

MEP, then the linktrace may fail. Use the

show ethernet cfm

maintenance-points remote crosscheck

command to verify that a MAC

address has been learned for the target MEP.

Link trace messages (LTMs) are sent as multicast CFM frames, and

forwarded from MIP to MIP, with each MIP generating a link trace reply,

up to the point at which the LTM reaches its destination or can no

longer be forwarded.

Link trace messages are used to isolate faults. However, this task can

be difficult in an Ethernet environment, since each node is connected

through multipoint links. Fault isolation is even more challenging since

the MAC address of the target node can age out in several minutes.

This can cause the traced path to vary over time, or connectivity lost if

faults cause the target MEP to be isolated from other MEPs in an MA.

Advertising