C

HAPTER

44

| CFM Commands

Fault Generator Operations

– 1345 –

D

EFAULT

S

ETTING

3 seconds

C

OMMAND

M

ODE

CFM Domain Configuration

C

OMMAND

U

SAGE

A fault alarm is issued when the MEP fault notification generator state

machine detects that a time period configured by this command has

passed with one or more defects indicated, and fault alarms are enabled at

or above the priority level set by the

mep fault-notify lowest-priority

command.

E

XAMPLE

This example set the delay time before generating a fault alarm.

Console(config)#ethernet cfm domain index 1 name voip level 3

Console(config-ether-cfm)#mep fault-notify alarm-time 10

Console(config-ether-cfm)#

mep fault-notify

lowest-priority

This command sets the lowest priority defect that is allowed to generate a

fault alarm. Use the no form to restore the default setting.

S

YNTAX

mep fault-notify lowest-priority priority
no fault-notify lowest-priority

priority – Lowest priority default allowed to generate a fault alarm.

(Range: 1-6)

D

EFAULT

S

ETTING

Priority level 2

C

OMMAND

M

ODE

CFM Domain Configuration

C

OMMAND

U

SAGE

A fault alarm can generate an SNMP notification. It is issued when the

MEP fault notification generator state machine detects that a configured

time period (see the

mep fault-notify alarm-time

command) has passed

with one or more defects indicated, and fault alarms are enabled at or

above the priority level set by this command. The state machine

transmits no further fault alarms until it is reset by the passage of a

configured time period (see the

mep fault-notify reset-time

command)

without a defect indication. The normal procedure upon receiving a

fault alarm is to inspect the reporting MEP’s managed objects using an

appropriate SNMP software tool, diagnose the fault, correct it, re-

examine the MEP’s managed objects to see whether the MEP fault

Advertising