2 setting the baud rate, Setting the baud rate – Lenze E94ARNE Regenerative power supply User Manual

Page 102

Advertising
background image

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Possible settings via DIP switches

102

L

EDS94ARNExxxx EN 2.3 - 06/2014

6.2.2

Setting the baud rate

The baud rate can be set via code

C00351

or via the DIP switches a ... d:

Tip!
The baud rate resulting from the setting of the DIP switches at the last mains

switching is displayed in

C00349/2

.

Switch positions

Baud rate

d

c

b

a

OFF

ON

ON

OFF

10 kbps

OFF

ON

OFF

ON

20 kbps

OFF

OFF

ON

ON

50 kbps

OFF

OFF

ON

OFF

125 kbps

OFF

OFF

OFF

ON

250 kbps

OFF

OFF

OFF

OFF

500 kbps

ON

ON

ON

OFF

800 kbps

OFF

ON

OFF

OFF

1 Mbps

OFF

ON

ON

ON

Automatic detection

Note!

Switch off the voltage supply of the standard device and then on again to

activate changed settings.

Advertising