Memory module has been removed [0x00680006, Safety module has been removed [0x00680007, Control card is defect [0x00680008 – Lenze E94ARNE Regenerative power supply User Manual

Page 211: Power section is defect [0x00680009, Mxi1: module is defect or missing [0x0068000a, Mxi2: module is defect or missing [0x0068000b, 0x00680008, 0x00680006, 0x0068000a, 0x0068000b

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

211

9400 regenerative power supply module | Parameter setting

Diagnostics & fault analysis

Error messages

Memory module has been removed [0x00680006]

Safety module has been removed [0x00680007]

Control card is defect [0x00680008]

Power section is defect [0x00680009]

MXI1: Module is defect or missing [0x0068000a]

MXI2: Module is defect or missing [0x0068000b]

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

You have tried to remove or change the memory module

during operation.

Switch off regenerative power supply module, insert

memory module, and switch on regenerative power

supply module again.

• If the error occurs again, the memory module is

defective and must be replaced.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

You have tried to remove or change the safety module

during operation.

Switch off regenerative power supply module, insert

safety module, and switch on regenerative power supply

module again.

• If the error occurs again, the safety module is

defective and must be replaced.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the control card.

Please contact Lenze.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the power section. Please contact Lenze.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify extension module in

module slot MXI1.

• Use a different extension module.

• Please contact Lenze.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify extension module in

module slot MXI2.

• Use a different extension module.

• Please contact Lenze.

Advertising