Parameter reference parameter list – Lenze E94ARNE Regenerative power supply User Manual

Page 274

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list

274

L

EDS94ARNExxxx EN 2.3 - 06/2014

102 Unbind/bind Ethernet module MXI2 Reinitialises the Ethernet interface of the Ethernet

communication module in the module slot MXI2.

• Required when a new IP or gateway address is to be

accepted without mains switching.

201 Activate parameter set 1

Loads parameter set 1 from the memory module.

• Only possible when the controller is inhibited and the

application has been stopped.

202 Activate parameter set 2

Loads parameter set 2 from the memory module.

• Only possible when the controller is inhibited and the

application has been stopped.

203 Activate parameter set 3

Loads parameter set 3 from the memory module.

• Only possible when the controller is inhibited and the

application has been stopped.

204 Activate parameter set 4

Loads parameter set 4 from the memory module.

• Only possible when the controller is inhibited and the

application has been stopped.

301 Archive parameter set 1

Saves the current parameter set as parameter set 1 in the

memory module.

302 Archive parameter set 2

Saves the current parameter set as parameter set 2 in the

memory module.

303 Archive parameter set 3

Saves the current parameter set as parameter set 3 in the

memory module.

304 Archive parameter set 4

Saves the current parameter set as parameter set 4 in the

memory module.

401 Internal command 401

For Lenze service only

730 Internal command 730

For Lenze service only

731 Internal command 731

For Lenze service only

732 Internal command 732

For Lenze service only

733 Internal command 733

For Lenze service only

800 Internal command 800

For Lenze service only

1001 Internal command 1001

For Lenze service only

1020 Internal command 1020

For Lenze service only

1021 Export parameters to file

For Lenze service only

1030 Format file system

Formats the file system of the memory module.

1040 Restore file system

Restores the file system of the memory module (low

level formatting).

• The low level formatting of the file system by the user

is only intended for the exceptional case when the

standard formatting is not possible anymore, e.g. due

to damaged internal management information.

10000 Prepare firmware update

Sets the regenerative power supply module to the

firmware update mode.

11000 Restart controller

Restarts the regenerative power supply module via

parameterisation.

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00002 | Device commands

Data type: UNSIGNED_32

Index: 24573

d

= 5FFD

h