9400 regenerative power supply module | Parameter setting

Device interface

Monitoring the device utilisation

86

L

EDS94ARNExxxx EN 2.3 - 06/2014

4.4

Monitoring the device utilisation

C00064

displays the device utilisation (I x t) over the last 180 seconds in [%].

If the value displayed in

C00064

exceeds the warning threshold set in

C00123

, the error

message "Device utilisation Ixt > C00123" is output and the error response set in

C00604

occurs (default setting: "Warning").

If the value displayed in

C00064

exceeds 100 %, the error message "Device utilisation

Ixt > 100 %" is output and the error response "Fault" occurs.
– The error can only be reset if the value displayed in

C00064

drops to < 95 % again.