4 monitoring the device utilisation, Monitoring the device utilisation – Lenze E94ARNE Regenerative power supply User Manual
Page 86
Advertising
9400 regenerative power supply module | Parameter setting
Device interface
Monitoring the device utilisation
86
L
EDS94ARNExxxx EN 2.3 - 06/2014
4.4
Monitoring the device utilisation
displays the device utilisation (I x t) over the last 180 seconds in [%].
If the value displayed in
exceeds the warning threshold set in
, the error
message "Device utilisation Ixt > C00123" is output and the error response set in
occurs (default setting: "Warning").
If the value displayed in
exceeds 100 %, the error message "Device utilisation
Ixt > 100 %" is output and the error response "Fault" occurs.
– The error can only be reset if the value displayed in
drops to < 95 % again.