C00076 | current contr. reset time, C00077 | service code, C00078 | service code – Lenze E94ARNE Regenerative power supply User Manual

Page 279: C00079 | service code, C00084 | filter resistance, C00085 | filter inductance, C00099 | firmware version, C00076, C00084, C00085

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

279

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00076

C00076

C00077

C00078

C00079

C00084

C00085

C00099

Parameter | Name:

C00076 | Current contr. reset time

Data type: UNSIGNED_32

Index: 24499

d

= 5FB3

h

Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 50.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00077 | Service code

Data type: UNSIGNED_32

Index: 24498

d

= 5FB2

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00078 | Service code

Data type: UNSIGNED_32

Index: 24497

d

= 5FB1

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00079 | Service code

Data type: UNSIGNED_8

Index: 24496

d

= 5FB0

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00084 | Filter resistance

Data type: UNSIGNED_32

Index: 24491

d

= 5FAB

h

Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Ohm

125.0000 0.2000 Ohm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C00085 | Filter inductance

Data type: UNSIGNED_32

Index: 24490

d

= 5FAA

h

Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range

(min. value | unit | max. value)

Lenze setting

0.000

mH

500.000 5.000 mH

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00099 | Firmware version

Data type: VISIBLE_STRING

Index: 24476

d

= 5F9C

h

Format: "xx.xx.xx.xx" (main version, subversion, release version, build number)

Read access  Write access  CINH  PLC STOP  No transfer