C00392 | can emergency delay time, C00393 | can result - bus scan, C00394 | service code – Lenze E94ARNE Regenerative power supply User Manual

Page 310: C00395 | service code, C00396 | service code, C00397 | service code, C00398 | service code, C00399 | service code, C00393, C00392

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00392

310

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00392

C00393

C00394

C00395

C00396

C00397

C00398

C00399

Parameter | Name:

C00392 | CAN emergency delay time

Data type: UNSIGNED_16

Index: 24183

d

= 5E77

h

Minimum time between two successive emergency telegrams.

• Setting "0" deactivates the inhibit time check.

• The delay time is entered in 1/10 ms. The code automatically rounds the entries down to the preceding full

millisecond.

• Mapping of the CANopen object

I-1015

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00393 | CAN result - bus scan

Data type: UNSIGNED_8

Index: 24182

d

= 5E76

h

Result of CAN bus scanning (see device commands under

C00002

).

• Subcode number 1 ... 128 corresponds to CAN node address 1 ... 128.

"CAN on board" system bus

Display range

(min. value | unit | max. value)

0

1

Subcodes

Information

C00393/1

Result of CAN bus scanning for CAN node address 1 ...

128

• "1" means that a node with the corresponding node

address has been found.

C00393/...
C00393/128

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00394 | Service code

Data type: UNSIGNED_32

Index: 24181

d

= 5E75

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00395 | Service code

Data type: UNSIGNED_32

Index: 24180

d

= 5E74

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00396 | Service code

Data type: UNSIGNED_32

Index: 24179

d

= 5E73

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00397 | Service code

Data type: UNSIGNED_32

Index: 24178

d

= 5E72

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00398 | Service code

Data type: UNSIGNED_32

Index: 24177

d

= 5E71

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00399 | Service code

Data type: INTEGER_32

Index: 24176

d

= 5E70

h

This code is used internally by the device and must not be overwritten by the user!

Advertising