9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C01902

C01902

C01903

C01905

C02104

C02108

Parameter | Name:

C01902 | Diagnostics X6: Max. baud rate

Data type: UNSIGNED_32

Index: 22673

d

= 5891

h

Maximum permissible baud rate of the standard device after determination of the baud rate at the diagnostics

interface X6

• Communication starts with the default baud rate (19200) of the standard device.
Selection list

(Lenze setting printed in bold)

9600 9600 baud

19200 19.200 baud
38400 38.400 baud
57600 57.600 baud

115200 115.200 baud
230400 230.400 baud
375000 375.000 baud
750000 750.000 baud

1500000 1.500.000 baud
3000000 3.000.000 baud

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01903 | Diagnostics X6: Change baud rate

Data type: UNSIGNED_32

Index: 22672

d

= 5890

h

New determination of the baud rate at the diagnostics interface X6
Selection list

(Lenze setting printed in bold)

1 Set a higher baud rate
0 Ignore changes

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01905 | Diagnostics X6: Curr. baud rate

Data type: UNSIGNED_32

Index: 22670

d

= 588E

h

Current baud rate at diagnostics interface X6
Display range

(min. value | unit | max. value)

0

3000000

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C02104 | Program auto-start

Data type: UNSIGNED_32

Index: 22471

d

= 57C7

h

Selection list

(Lenze setting printed in bold)

0 OFF
1 Autom. after mains connection

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C02108 | Program status

Data type: UNSIGNED_8

Index: 22467

d

= 57C3

h

Selection list

(display only)

1 Program stopped
0 Program is running
2 Program stopped at breakpoint

Read access  Write access  CINH  PLC STOP  No transfer