9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

General information

6.1.1

General data and operating conditions

6.1.2

Supported protocols

Area

Values

Communication profile

CANopen (DS301 V4.02)

Communication medium

DIN ISO 11898

Network topology

Line terminated at both ends (e.g. by means of Sub-D plug, type EWZ0046)

Adjustable node addresses

1 ... 127

• Adjustable via DIP switch on the memory module or via code

C00350

.

Max. number of nodes

127

Baud rate

10, 20, 50, 125, 250, 500, 800, 1000 kbps or automatic detection

• Adjustable via DIP switch on the memory module (exception: MM1xx

memory module) or via code

C00351

.

Process data

• Max. 4 TPDOs with 1 ... 8 bytes

• Max. 4 RPDOs with 1 ... 8 bytes

Parameter data

Max. 10 client and server SDO channels with 1 ... 8 bytes

TPDO transmission mode

• At change of data

• Time-controlled 1 ... x ms

• After 1 ... 240 received sync telegrams

Category

Protocol

Standard PDO protocols

PDO write

PDO read

SDO protocols

SDO download

SDO download initiate

SDO download segment
SDO upload

SDO upload initiate

SDO upload segment
SDO abort transfer
SDO block download

SDO block download initiate

SDO block download end
SDO block upload

SDO block upload initiate

SDO block upload end

NMT protocols

Start remote node (master and slave)
Stop remote node (slave)
Enter pre-operational (slave)
Reset node (slave and local device)
Reset communication (slave)

Monitoring protocols

Node guarding (master and slave)
Heartbeat (heartbeat producer and heartbeat consumer)