9400 regenerative power supply module | Parameter setting

Regenerative power supply module application

Assignment of the I/O terminals

34

L

EDS94ARNExxxx EN 2.3 - 06/2014

3.3

Assignment of the I/O terminals

In the following tables the Lenze assignment of the I/O terminals for the "Regenerative

power supply module" application is listed.

If required, the default signal configuration can be easily reconfigured via the

parameterisation dialog on the Application parameters tab, or via parameterisation of

the multiplexer parameters assigned.

Digital inputs

Digital outputs

Terminal

Assignment (Lenze setting)

X5

RFR

Controller enable

DI1

Inhibit regenerative feedback

• Function also possible via bit 01 of control word 1.

DI2

Activate brake chopper

• Function also possible via bit 02 of control word 1.

DI3

Reset (acknowledge) error

• A pending error message can be reset (acknowledged) by a LOW-HIGH edge if the cause of

the error message has been eliminated.

• Function also possible via bit 07 of control word 1.

DI4

-

DI5

-

DI6

-

DI7

-

DI8

-

Terminal

Signal (Lenze setting)

Signal configuration

X4

DO1

"Ready for regenerative feedback" state

• Mains voltage is applied.

• Charging of DC bus is completed.

• There is no short circuit or earth fault.

• There is no device overload, i.e. the device utilisation (

C00064

) is

below the warning threshold set in

C00123

.

C03100/1

DO2

"Filter overtemperature" state

C03100/2

DO3

"Fault active - acknowledgement required" state

• A monitoring function with the "Fault" response has been triggered

and the regenerative power supply module is in the "Fault active"

device state.

C03100/3

DO4

"Warning active" state

• A filter overload or device overload warning has occurred or another

monitoring function with the "Warning" error response has been

triggered and the regenerative power supply module is in the

"Warning active" device state.

C03100/4