32 archive parameter sets 1, Archive parameter sets 1 – Lenze E94ARNE Regenerative power supply User Manual

Page 73

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

73

9400 regenerative power supply module | Parameter setting

Device interface

Device commands

4.1.32

Archive parameter sets 1 ... 4

In addition to the start parameters, up to four more parameter sets can be stored in the

memory module for each application. This, for instance, serves to define different

controller settings for an application, which can then be simply activated via device

command.
The following device commands can be used to archive the current parameter settings of

the regenerative power supply module as parameter sets 1 ... 4 for the active application in

the memory module:

C00002

= "301: Archive parameter set 1"

C00002

= "302: Archive parameter set 2"

C00002

= "303: Archive parameter set 3"

C00002

= "304: Archive parameter set 4"

[4-10] Example: "Archive parameter set 1" function

Previously archived parameter settings will be overwritten with the current parameter

settings!

* In this example application 1 is the active application

PS 4

PS 3

PS 2

Application 2

PS 1

PS

PS 4

PS 3

PS 2

Memory module MM

PS

9400

PS

RAM

Firmware

Application 1*

Application 1*

PS

PS 1