9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Implemented CANopen objects

146

L

EDS94ARNExxxx EN 2.3 - 06/2014

I-1029

Error behaviour
0

Highest subindex supported

-

1

Communication error

C00625

I-1200

SDO1 server parameter
0

Highest subindex supported

-

1

COB-ID client −> server (rx)

C00372/1

2

COB-ID server −> client (tx)

C00373/1

I-1201

...

I-1209

SDO2 ... SDO10 server parameter
0

Highest subindex supported

-

1

COB-ID client −> server (rx)

C00372/2...10

2

COB-ID server −> client (tx)

C00373/2...10

3

Node ID of the SDO client

-

I-1400

...

I-1403

RPDO1 ... RPDO4 communication parameter
0

Highest subindex supported

-

1

COB-ID used by RPDO

C00321/1...4

2

Transmission type

C00323/1...4

3

Inhibit time

-

4

Compatibility entry

-

5

Event timer

-

I-1600

...

I-1603

RPDO1 ... RPDO4 mapping parameter
0

Number of mapped application objects in PDO

-

1 ... 8

Application object 1 ... 8

-

I-1800

...

I-1803

TPDO1 ... TDDO4 communication parameter
0

Highest subindex supported

-

1

COB-ID used by TPDO

C00320/1...4

2

Transmission type

C00322/1...4

3

Inhibit time

C00324/1...4

4

Reserved

-

5

Event timer

C00356/1...4

I-1A00

...

I-1A03

TPDO1 ... TDDO4 mapping parameter
0

Number of mapped application objects in PDO

-

1 ... 8

Application object 1 ... 8

-

CANopen object