C00351 | can baud rate, C00352 | can slave/master, C00356 | can tpdox cycle time – Lenze E94ARNE Regenerative power supply User Manual

Page 300: C00351, S) and, C00352, C00356/1, Configure the controller as nmt master: set, C00356/2, C00356/3

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00351

300

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00351

C00352

C00356

Parameter | Name:

C00351 | CAN baud rate

Data type: UNSIGNED_8

Index: 24224

d

= 5EA0

h

• A change of the baud rate only becomes effective after a CAN reset node.

• Overwriting the value deactivates a possibly existing hardware assignment of the node address.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 500 kbps
1 250 kbps
2 125 kbps
3 50 kbps
4 1 Mbps
5 20 kbps
6 10 kbps
8 Reserved
9 Reserved

10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 800 kbps
15 Reserved

255 Automatic recognition

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00352 | CAN slave/master

Data type: UNSIGNED_8

Index: 24223

d

= 5E9F

h

If "1" is entered and saved, the drive will act as a CAN master after mains switching.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 Slave
1 Master

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00356 | CAN TPDOx cycle time

Data type: UNSIGNED_16

Index: 24219

d

= 5E9B

h

TPDO event time according to DS301 V4.02

• With a value unequal "0", the TPDO will be sent independently of the transmission type after the set time has

elapsed.

• Mapping of CANopen objects

I-1800/5

...

I-1803/5

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Information

C00356/1

0 ms

Cycle time for TPDO1 ... TPDO4

C00356/...
C00356/4

Read access  Write access  CINH  PLC STOP  No transfer

Advertising