9400 regenerative power supply module | Parameter setting
Oscilloscope
Operation
178
L
EDS94ARNExxxx EN 2.3 - 06/2014
7.4.4
Starting recording
Click Start to start recording.
To obtain a maximum sample rate when recording the variable values, the data are first
stored in the measured data memory of the regenerative power supply module and then
transferred as a data record to the PC.
The current recording status is displayed in the status bar.
Negative edge For triggering on a Boolean variable:
• Trigger activation requires a TRUE-FALSE transition.
For triggering on a different variable:
• For trigger activation, the selected trigger value must be fallen below.
Change For triggering on a Boolean variable:
• Trigger activation requires a state change.
For triggering on a different variable:
• For trigger activation, the current value must be different than the last value.
Setting
Function