C00166 | error description, C00167 | service code, C00168 | error number – Lenze E94ARNE Regenerative power supply User Manual

Page 286: C00169 | logbook - event filter, C00171 | service code, Displayed in, C00168, Or error cause see error description, C00166, Decimal format in the internal error buffer

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00166

286

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00166

C00167

C00168

C00169

C00171

Parameter | Name:

C00166 | Error description

Data type: VISIBLE_STRING

Index: 24409

d

= 5F59

h

Error description for the error number displayed in

C00168

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00167 | Service code

Data type: VISIBLE_STRING

Index: 24408

d

= 5F58

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00168 | Error number

Data type: UNSIGNED_32

Index: 24407

d

= 5F57

h

Display of the error number of the first error with highest priority
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00169 | Logbook - event filter

Data type: BITFIELD_32

Index: 24406

d

= 5F56

h

Bit-coded word for filtering system events (trouble, warning, information)

• A set bit excludes the corresponding event from being entered into the logbook.

From software version V2.0 onwards,

bit 0 can be used to activate the option of suppressing successive identical

logbook entries ("multiple entries"). In this case, only the time stamp of the last (most recent) entry is saved

together with the number of occurrences of the event.

Logbook

Value is bit-coded:

Bit 0 No multiple entries
Bit 1 Fault
Bit 2 Trouble
Bit 4 Warning locked
Bit 5 Warning
Bit 6 Information

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00171 | Service code

Data type: UNSIGNED_32

Index: 24404

d

= 5F54

h

This code is used internally by the device and must not be overwritten by the user!