9400 regenerative power supply module | Parameter setting

Device interface

Device commands

4.1.5

Save selected application

After mains switching, the regenerative power supply module always loads the default

start application from the memory module, even if a different application has been active

before.
The device command

C00002

= "7: Save selected application" can be used to define the

active application as start application.

[4-4]

"Save selected application" function

When this device command is executed, the parameter set is also saved automatically.

The number of the currently active application is displayed in

C00007

.

Possible status displays for this device command

Related device commands

Activate application

( 42)

Start application

( 48)

Stop application

( 49)

* In this example the active application 2 is defined as start application

PS

9400

RAM

Firmware

Application 2*

PS

Application 3

Memory module MM

Application 1

Application 2*

PS

Status (

C00003

)

Meaning

492802 Device command in process

458752 Device command executed successfully

458753 General fault