35 Restart program

Executes a reset (warm start).

• All variables except for the RETAIN variables are reset

to their initialisation values.

• The situation corresponds to a power failure or a

switching off and on again of the regenerative power

supply module (warm start) while the program is

running.

36 Reset runtime measurement

Runtime measurement

41 Inhibit controller
42 Enable controller
43 Reset error
47 Internal command 47

For Lenze service only

48 Internal command 48

For Lenze service only

60 Reset max DC power mot.

From software version V2.0 onwards

Resets the value displayed in

C00143/1

to zero.

Display of peak power

61 Reset max DC power reg.

From software version V2.0 onwards

Resets the value displayed in

C00143/2

to zero.

Display of peak power

62 Reset max line power reg.

From software version V2.0 onwards

Resets the value displayed in

C00143/3

to zero.

Display of peak power

65 Reset transmitted energy

From software version V2.0 onwards

Resets the value displayed in

C00145/1

to zero.

Display of transmitted and regenerated energy

66 Reset regenerated energy

From software version V2.0 onwards

Resets the value displayed in

C00145/2

to zero.

Display of transmitted and regenerated energy

91 CAN on-board: Reset node

Reinitialises the "CAN on board" interface.

• Required when the baud rate, node address or

identifiers have been changed.

"CAN on board" system bus

92 CAN module: Reset node

Reinitialises CANopen interface of the CANopen

communication module.

• Required when the baud rate, node address or

identifiers have been changed.

93 CAN on-board: Pred.Connect.Set

Sets basic identifier for the "CAN on board" interface

according to the "Predefined Connection Set" (DS301

V4.02).

"CAN on board" system bus

94 CAN module: Pred.Connect.Set

Sets basic identifier for the CANopen interface of the

CANopen communication module according to the

"Predefined Connection Set" (DS301 V4.02).

95 CAN on-board: Identify node

Identifies the nodes connected to the "CAN on board"

interface.

• The result of the CAN bus scan is displayed in

C00393

.

"CAN on board" system bus

96 CAN module: Identify node

Identifies the nodes connected to the CANopen interface

of the CANopen communication module.

• The result of the CAN bus scan is displayed in C13393

(for MXI1) or C14393 (for MXI2).

101 Unbind/bind Ethernet module MXI1 Reinitialises the Ethernet interface of the Ethernet

communication module in the module slot MXI1.

• Required when a new IP or gateway address is to be

accepted without mains switching.