C00378 | can delay boot-up - operational, C00379 | service code, C00381 | can heartbeat producer time – Lenze E94ARNE Regenerative power supply User Manual

Page 307: C00382 | can guard time, C00383 | can life time factor, C00378, Serves to, C00382, C00383, C00381

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

307

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00378

C00378

C00379

C00381

C00382

C00383

Parameter | Name:

C00378 | CAN delay boot-up - Operational

Data type: UNSIGNED_16

Index: 24197

d

= 5E85

h

Time which must elapse after mains switching before the CAN NMT master puts the "Start remote node" telegram

on the bus.

• The delay time is only used when the master bit is activated (

C00352

) and the device has been restarted.

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 3000 ms

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00379 | Service code

Data type: UNSIGNED_8

Index: 24196

d

= 5E84

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00381 | CAN Heartbeat Producer Time

Data type: UNSIGNED_16

Index: 24194

d

= 5E82

h

Time interval for sending the heartbeat telegram to the consumer(s).

• The parameterised time interval is rounded down to an integer multiple of 5 ms.

• The heartbeat telegram is sent automatically if a time interval > 0 ms is set. In this case the "node guarding"

monitoring function is deactivated.

• Mapping of the CANopen object

I-1017

(see DS301 V4.02).

"CAN on board" system bus: heartbeat protocol

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00382 | CAN Guard Time

Data type: UNSIGNED_16

Index: 24193

d

= 5E81

h

After the set guard time multiplied by the life time factor (

C00383

), a node guarding telegram must have been

received.

• Mapping of the CANopen object

I-100C

(see DS301 V4.02).

"CAN on board" system bus: node guarding protocol

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00383 | CAN Life Time Factor

Data type: UNSIGNED_8

Index: 24192

d

= 5E80

h

The life time factor multiplied by the guard time (

C00382

) results in the time during which a node guarding

telegram must have been received.

• Mapping of the CANopen object

I-100D

(see DS301 V4.02).

"CAN on board" system bus: node guarding protocol

Setting range

(min. value | unit | max. value)

Lenze setting

0

255 0

Read access  Write access  CINH  PLC STOP  No transfer