C00214 | required safety module, C00217 | service code, C00218 | application: id number – Lenze E94ARNE Regenerative power supply User Manual

Page 292: C00219 | service code, C00225 | service code, C00227 | behaviour due to change of parameterset, C00308 | service code

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00214

292

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00214

C00217

C00218

C00219

C00225

C00227

C00308

Parameter | Name:

C00214 | Required safety module

Data type: UNSIGNED_8

Index: 24361

d

= 5F29

h

Note: The regenerative power supply module does not support any safety engineering.

• The SM0 safety module (without safety engineering) must be inserted into the regenerative power supply

module.

• If a different safety module is detected, an error (trouble) will be activated. The error can only be reset by mains

switching.

Selection list

(Lenze setting printed in bold)

1 SM0

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00217 | Service code

Data type: UNSIGNED_32

Index: 24358

d

= 5F26

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00218 | Application: ID number

Data type: UNSIGNED_32

Index: 24357

d

= 5F25

h

Display range

(min. value | unit | max. value)

0

0

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00219 | Service code

Data type: UNSIGNED_32

Index: 24356

d

= 5F24

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00225 | Service code

Data type: UNSIGNED_32

Index: 24350

d

= 5F1E

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00227 | Behaviour due to change of parameterset

Data type: UNSIGNED_32

Index: 24348

d

= 5F1C

h

From software version V2.0 onwards

If you select "1" in the corresponding subcode, you can exclude a module inserted in slot MXI1 / MXI2 from the

parameter set changeover via the device command "Activate parameter set n".

• This significantly speeds up the parameter set changeover, especially for active modules.

• An exclusion from the parameter set changeover is useful, for instance, if different parameter sets are used (e.g.

for different tools on the machine), but the parameters for the module always remain the same (e.g.

communication parameters).

Selection list

(Lenze setting printed in bold)

0 Included
1 Excluded

Subcodes

Lenze setting

Information

C00227/1

0: Included

Change of parameter set: MXI1

C00227/2

0: Included

Change of parameter set: MXI2

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00308 | Service code

Data type: UNSIGNED_16

Index: 24267

d

= 5ECB

h

This code is used internally by the device and must not be overwritten by the user!