9400 regenerative power supply module | Parameter setting

Diagnostics & fault analysis

Error messages

Application has stopped [0x006a000e]

Faulty application parameter [0x006a0010]

Division by zero [0x006a0011]

Pointer access in impermissible memory area [0x006a0012]

Application has started [0x006a0013]

Application has stopped [0x006a0014]

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The application has been stopped using the device

command

C00002

="32". All user tasks are stopped.

Restart application with device command

C00002

="31".

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An invalid parameter description has occurred.

Transfer application and parameter set to the

regenerative power supply module again.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

A forbidden division by zero occurred in the application.

The division has been intercepted and the divisor has

been replaced by the value "1".

Exchange application.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An invalid pointer access to a protected area occurred in

the application.

Exchange application.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The application in the regenerative power supply

module has been started.

- (Information only)

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The application in the regenerative power supply

module has been stopped.

- (Information only)