C00360 | can telegram and error counter, C00361 | can bus load, C00360/1 – Lenze E94ARNE Regenerative power supply User Manual

Page 302: C00360/2, C00360/3, C00360/4, C00360/5, C00360/6, C00360/7, C00360/8

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00360

302

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00360

C00361

Parameter | Name:

C00360 | CAN telegram and error counter

Data type: UNSIGNED_16

Index: 24215

d

= 5E97

h

• After power-on, counting starts with "0".

• After the maximum value has been reached, counting restarts with "0".

"CAN on board" system bus

Display range

(min. value | unit | max. value)

0

65535

Subcodes

Information

C00360/1

Stuffing bit error counter

• More than five identical bits have been detected.

C00360/2

Format error counter

• CAN frame has not been complied with.

C00360/3

Acknow. error counter

• No device has acknowledged the telegram.

C00360/4

Bit 1 error counter

• "1" should be sent after bus arbitration, but "0" was

read.

C00360/5

Bit 0 error counter

• "0" should be sent after bus arbitration, but "1" was

read.

C00360/6

CRC error counter

• Check sum check has indicated an error.

C00360/7

Tx telegram counter

• Correctly received telegrams.

C00360/8

Rx telegram counters

• Correctly transmitted telegrams.

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00361 | CAN bus load

Data type: UNSIGNED_32

Index: 24214

d

= 5E96

h

Switch off the device and then on again or use the device command "Reset node" (

C00002

) to reset the display of

the maximum node load (subcodes 4 ... 6).

"CAN on board" system bus

Display range

(min. value | unit | max. value)

0

%

100

Subcodes

Information

C00361/1

Current node load in Tx direction

C00361/2

Current node load in Rx direction

C00361/3

Current node load through faulty telegrams

C00361/4

Maximum node load in Tx direction

C00361/5

Maximum node load in Rx direction

C00361/6

Maximum node load through faulty telegrams

Read access  Write access  CINH  PLC STOP  No transfer