1 device commands, Device commands – Lenze E94ARNE Regenerative power supply User Manual

Page 37

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

37

9400 regenerative power supply module | Parameter setting

Device interface

Device commands

4.1

Device commands

The following subchapters describe the device commands of the regenerative power

supply module, which are available in

C00002

and which can be executed using the keypad

or via the »Engineer« when an online connection has been established.

Activating frequently required device commands via the toolbar
Frequently required device commands can be executed very easily directly via the Toolbar

of the »Engineer« when an online connection has been established.

Note!

Before switching off the supply voltage after a device command has been

executed, check via the status display in

C00003

that the device command has

been executed successfully!
The meaning of the status display in

C00003

can be obtained from the

subchapter for the corresponding device command.

Icon

Function

Enable controller

Inhibit controller

Start application

Stop application

and

Inhibit controller

Note!

Device commands that can be executed via the Toolbar of the »Engineer« always

affect the element that is currently selected in the Project View and all

subelements!
• If, for example, a system module is selected in the Project view instead of the

regenerative power supply module, the corresponding device command will

be activated in all lower-level regenerative power supply modules &

controllers that are currently connected online with the »Engineer«.

Before the corresponding action is executed, a confirmation prompt is displayed

to ask you if this action should really be carried out.