I-1802/1, I-1803/1, I-1803 – Lenze E94ARNE Regenerative power supply User Manual

Page 167: Communicat

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

167

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Implemented CANopen objects

I-1802

Communication parameter for the transmission of process data via TPDO3

For the assignment of the data telegram see object

I-1800

.

I-1803

Communication parameter for the transmission of process data via TPDO4

For the assignment of the data telegram see object

I-1800

.

Index:

I-1802

Name:

TPDO3 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by TPDO

0x380 + node ID

0

4294967295 rw

U32

2: Transmission type

254

0

255 rw

U8

3: Inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: Reserved

-

- (reserved, read or write access results in the error

message 0x06090011)

rw

U8

5: Event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

Identifier TPDO3

• The basic setting corresponds to the "Predefined

Connection Set": identifier = 0x380 + node ID

C00320/3

2

TPDO transmission type according to DS301 V4.02

Transmission type ( 113)

C00322/3

3

Minimum time interval between the transmission of

two identical TPDOs (see DS301 V4.02).

C00324/3

5

Cycle time for the transmission of PDOs with

transmission type "254".

C00356/3

Index:

I-1803

Name:

TPDO4 communication parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

5

- (read access only)

ro

U8

1: COB-ID used by TPDO

0x480 + node ID

0

4294967295 rw

U32

2: Transmission type

254

0

255 rw

U8

3: Inhibit time

0 ms

0

0.1 ms

65535 rw

U16

4: Reserved

-

- (reserved, read or write access results in the error

message 0x06090011)

rw

U8

5: Event timer

0 ms

0

ms

65535 rw

U16

Subindex

Meaning

Lenze code

1

Identifier TPDO4

• The basic setting corresponds to the "Predefined

Connection Set": identifier = 0x480 + node ID

C00320/4

2

TPDO transmission type according to DS301 V4.02

Transmission type ( 113)

C00322/4

3

Minimum time interval between the transmission of

two identical TPDOs (see DS301 V4.02).

C00324/4

5

Cycle time for the transmission of PDOs with

transmission type "254".

C00356/4