3 commissioning example, Commissioning example – Lenze E94ARNE Regenerative power supply User Manual

Page 143

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

143

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Monitoring

6.9.2.3

Commissioning example

Task
A 9400 controller configured as heartbeat consumer (node 2) is to monitor another 9400

controller (heartbeat producer; node 1).

The heartbeat producer is to send a heartbeat telegram to the heartbeat consumer

every 10 ms.

The heartbeat consumer monitors the arrival of the heartbeat telegram. If an error

occurs, a response is to be initiated.

Parameterising the heartbeat producer (node 1)

1. Set the heartbeat producer time (

C00381

) to 10 ms.

Parameterising the heartbeat consumer (node 2)

1. Configure the heartbeat monitoring in

C00385

.

– Note: The heartbeat consumer time must be longer than the heartbeat producer

time set for the monitored node in

C00381

.

– The value to be entered in a free subcode (1 ... 32) is "0x0001000F". It consists of the

following components:

2. Go to

C00613/1...32

and set the respective responses for the monitoring functions

parameterised in

C00385/1...32

, which are to be initiated in the consumer when a

"heartbeat event" occurs.

Tip!

C00346

displays the activity of the monitoring functions parameterised in

C00385/1...32

in a bit-coded manner.

C00347/1...32

display the heartbeat states of the monitored nodes.

C00625

serves to set the state change for a "heartbeat event".

Heartbeat telegram

The heartbeat telegram from the producer has the following identifier:

Identifier (COB-ID) = 1792 + node address of the producer = 1792 + 1 = 1793 = 0x701

Bit 31 ... bit 24

Reserved

Bit 23 ... bit 16

Node address

of the producer

Bit 15 ... bit 0

Heartbeat consumer time

(integer multiple of 5 ms)

0x00

0x01

15 [ms] = 0x000F

Advertising