1 general information, General information – Lenze E94ARNE Regenerative power supply User Manual

Page 98

Advertising
background image

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

General information

98

L

EDS94ARNExxxx EN 2.3 - 06/2014

6.1

General information

For many years the system bus (CAN) based on the CANopen communication profile has

been integrated in Lenze controllers. Due to the lower number of data objects available,

the functionality and compatibility of the old system bus are lower as compared with

CANopen. For parameter setting, two parameter data channels are always available to the

user while CANopen provides only one active parameter data channel (along with the

possibility to establish further channels).
The system bus (CANopen) integrated in the Servo Drives 9400 has been developed from

the system bus (CAN) used in the controllers of the ”9300” series, and it has the following

features:

Full compatibility to CANopen DS301 V4.02.

Support of the NMT master/slave function "Node Guarding" (DS301 V4.02).

Support of the NMT slave function "Heartbeat" (DS301 V4.02).

No restrictions regarding the selection of node addresses.

Number of parameterisable server and client SDO channels:
– Max. 10 channels with 1 ... 8 bytes

Number of parameterisable PDO channels:
– Max. 4 transmit PDOs (TPDOs) with 1 ... 8 bytes
– Max. 4 receive PDOs (RPDOs) with 1 ... 8 bytes

All PDO channels are equivalent in terms of functionality.

Data reception monitoring of RPDOs

Telegram counters for SDOs and PDOs

Bus state diagnostics

Boot-up telegram generation

Emergency telegram generation

Reset-node telegram generation (for master configuration).

Sync telegram generation and response to sync telegrams:
– Sending/reception of data
– Synchronisation of the device's internal time base

Abort codes

Ability to parameterise all "CAN on board" functions via codes.

Object directory (all mandatory functions, optional functions, indexes)