9400 regenerative power supply module | Parameter setting

Regenerative power supply module application

Parameterising the brake chopper/brake resistor

The brake chopper/brake resistor can be parameterised in the »Engineer» on the

Application parameters tab, dialog level Overview Brake chopper/resistor:

Short overview: Parameters for braking operation

Parameter

Information

Lenze setting

Value Unit

C00129

Brake resistor value

180.0 Ohm

C00130

Rated power of brake resistor

5600 W

C00131

Therm. capacity brake resistor

485 kWs

C00132

Activation brake chopper

At overvoltage and overcurrent

C00133

Ref: Brake chopper utilisation

Minimum resistance (C00134)

C00134

Minimum brake resistance

- Ohm

C00137

Brake transistor utilisation

- %

C00138

Brake resistor utilisation

- %

C00173

Mains voltage

400/415 V

C00181

Red. brake chopper threshold

0 V

C00569

Resp. brake trans. ixt > C00570

Warning

C00570

Warning thres. brake transistor

90 %

C00571

Resp. brake resist. i2t > C00572

Warning

C00572

Warning thres. brake resistor

90 %

C00573

Resp. to overload brake trans.

No response

C00574

Resp. to overtemp. brake resist.

No response

C00600

Resp. to DC bus overvoltage

Trouble

Highlighted in grey = display parameter