9400 regenerative power supply module | Parameter setting

Device interface

Device commands

40

L

EDS94ARNExxxx EN 2.3 - 06/2014

4.1.2

Load start parameters

The

C00002

= "1: Load start parameters" device command can be used to reload the start

parameters of the active application from the memory module into the regenerative

power supply module:

[4-2]

"Load start parameters" function

Only possible when the controller is inhibited and the application has been stopped.

All parameter changes made since the last saving of the parameter set will get lost!

This device command only has an impact on the settings of the operating system,

application, and module parameters, the active application remains unchanged.

Possible status displays for this device command

Related device commands

Save start parameters

( 44)

Load Lenze setting

( 39)

* In this example application 1 is the active application

PS

9400

RAM

Firmware

Application 1*

PS

Application 3

PS

Application 2

PS

Memory module MM

PS

Application 1*

Status (

C00003

)

Meaning

99586 Device command in process

65536 Device command executed successfully

65537 General fault
99371 Fault while reading the parameter set partition
99374 No memory module available

104960 CAN fault

... ...

105215 CAN fault