C01501 | resp. to comm. error with mxi1, C01502 | resp. to comm. error with mxi2, C01510 | ethernet ip address client x – Lenze E94ARNE Regenerative power supply User Manual

Page 330: C01511 | ethernet status client x, C01501

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C01501

330

L

EDS94ARNExxxx EN 2.3 - 06/2014

C01501

C01502

C01510

C01511

Parameter | Name:

C01501 | Resp. to comm. error with MXI1

Data type: UNSIGNED_32

Index: 23074

d

= 5A22

h

Response to communication error between "intelligent" module in module slot 1 and standard device
Selection list

(Lenze setting printed in bold)

0 No response
1 Fault
4 Warning locked
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01502 | Resp. to comm. error with MXI2

Data type: UNSIGNED_32

Index: 23073

d

= 5A21

h

Response to communication error between "intelligent" module in module slot 2 and standard device
Selection list

(Lenze setting printed in bold)

0 No response
1 Fault
4 Warning locked
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01510 | Ethernet IP address client x

Data type: VISIBLE_STRING

Index: 23065

d

= 5A19

h

Display of the three possible server channels

• If a client is connected with one of these server channels, the IP address and the port of the client are displayed

in the form of "xxx.xxx.xxx.xxx : yyyy".

• If no client is connected with the server channel, "---.---.---.--- : ----" is displayed.
Subcodes

Information

C01510/1

Server channel 1 ... 3

C01510/...
C01510/3

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01511 | Ethernet status client x

Data type: UNSIGNED_8

Index: 23064

d

= 5A18

h

States of the three possible server channels
Selection list

(display only)

0 Not connected
1 Connected
2 Stop
3 Unknown status

Subcodes

Information

C01511/1

State of server channel 1 ... 3

C01511/...
C01511/3

Read access  Write access  CINH  PLC STOP  No transfer