9 internal interfaces, 1 ls_analoginput - analog inputs, Internal interfaces – Lenze E94ARNE Regenerative power supply User Manual

Page 255: Ls_analoginput - analog inputs, 9internal interfaces

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

255

9400 regenerative power supply module | Parameter setting

Internal interfaces

LS_AnalogInput - analog inputs

9

Internal interfaces

This chapter gives information about the system blocks of the regenerative power supply

module. The system blocks are fixedly integrated in the runtime system and provide the

application in the »Engineer« function block editor with the internal interfaces for the I/Os

and for the device and line interface.

9.1

LS_AnalogInput - analog inputs

The LS_AnalogInput system block represents the analog inputs in the function block

editor.

Output

Data type

Value/meaning

AIN1_dnIn_n

DINT

Analog input 1

• Scaling:

±2

30

≡ ±10 V for use as voltage input

±2

30

≡ ±20 mA for use as current input

AIN2_dnIn_n

DINT

Analog input 2

• Scaling: ±2

30

≡ ±10 V

AIN1_bCurrentError

BOOL

Status signal "Current input error"

• Only when analog input 1 is used as current input.

• Application: Cable-breakage monitoring of the 4 ...20 mA circuit.

TRUE |I

AIN1

| < 2 mA

A1+

A1-

A1-

A1R

A2+

A2-

AIN1_dnIn_n

AIN1_bCurrentError

AIN2_dnIn_n

X3

LS_AnalogInput

250

C02731/1 C02730/1 C02732/1

C02731/2 C02730/2 C02732/2

C02800/1

C02800/2