C01206 | counter: mains switching, C01208 | counter: heatsink overtemp, C01209 | counter: housing overtemp – Lenze E94ARNE Regenerative power supply User Manual

Page 328: C01211 | service code, C01212 | counter: power section overload, C01213 | service code, C01214 | internal clock

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C01206

328

L

EDS94ARNExxxx EN 2.3 - 06/2014

C01206

C01208

C01209

C01211

C01212

C01213

C01214

Parameter | Name:

C01206 | Counter: Mains switching

Data type: UNSIGNED_16

Index: 23369

d

= 5B49

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01208 | Counter: Heatsink overtemp.

Data type: UNSIGNED_16

Index: 23367

d

= 5B47

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01209 | Counter: Housing overtemp.

Data type: UNSIGNED_16

Index: 23366

d

= 5B46

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01211 | Service code

Data type: UNSIGNED_32

Index: 23364

d

= 5B44

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C01212 | Counter: Power section overload

Data type: UNSIGNED_16

Index: 23363

d

= 5B43

h

Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C01213 | Service code

Data type: UNSIGNED_32

Index: 23362

d

= 5B42

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C01214 | Internal clock

Data type: VISIBLE_STRING

Index: 23361

d

= 5B41

h

Display of the device's system time in the format "dd/mm/yyyy hh:mm:ss"

• Time and date are set via

C01215

.

If the MM440 memory module with real-time clock is plugged into the regenerative power supply module, the

internal clock is adjusted to the real-time clock every time the power is switched on and every 24 hours at 0:00

o'clock.

• The daily adjustment is executed on a low-priority level. This is why it may take some seconds until the adjusted

time is displayed.

• During the adjustment process, status information of the real-time clock is also queried and error messages are

entered into the logbook if necessary.

Note:

If a memory module without real-time clock is plugged into the regenerative power supply module, the internal

clock is initialised with "01.01.1970 00:00:00" every time the power is switched on.

Read access  Write access  CINH  PLC STOP  No transfer