C02801 | analog output x: output signal, C02802 | status word: digital outputs, C02803 | status word: digital inputs – Lenze E94ARNE Regenerative power supply User Manual

Page 338: C02810 | touch probe x: delay time, C02801/1, C02801/2, C02803, C02802

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C02801

338

L

EDS94ARNExxxx EN 2.3 - 06/2014

C02801

C02802

C02803

C02810

Parameter | Name:

C02801 | Analog output x: Output signal

Data type: INTEGER_16

Index: 21774

d

= 550E

h

Scaling: -16384 ≡ -100 %, +16383 ≡ +100 %
Display range

(min. value | unit | max. value)

-16384

16383

Subcodes

Information

C02801/1

Analog output 1: Output signal

C02801/2

Analog output 2: Output signal

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C02802 | Status word: Digital outputs

Data type: BITFIELD_32

Index: 21773

d

= 550D

h

Display of the hexadecimal value of the digital outputs

• Important: All digital levels are indicated without considering the level logic. Internal signals are displayed as

well.

Display range

(min. value | unit | max. value)

0x

0x

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C02803 | Status word: Digital inputs

Data type: BITFIELD_32

Index: 21772

d

= 550C

h

Display of the hexadecimal value of the digital inputs

• Important: All digital levels are indicated without considering the level logic. Internal signals are displayed as

well.

Display range

(min. value | unit | max. value)

0x

0x

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C02810 | Touch probe x: Delay time

Data type: UNSIGNED_32

Index: 21765

d

= 5505

h

The set delay time will be considered when the position is determined at the touch probe time and will be used to

compensate for dead times, if necessary.

• Please observe also the setting of the input filter for the digital inputs (

C02830

).

Setting range

(min. value | unit | max. value)

0

μs

7000

Subcodes

Lenze setting

Information

C02810/1

0 μs

TP1 (DI1): Delay time

C02810/2

0 μs

TP2 (DI2): Delay time

C02810/3

0 μs

TP3 (DI3): Delay time

C02810/4

0 μs

TP4 (DI4): Delay time

C02810/5

0 μs

TP5 (DI5): Delay time

C02810/6

0 μs

TP6 (DI6): Delay time

C02810/7

0 μs

TP7 (DI7): Delay time

C02810/8

0 μs

TP8 (DI8): Delay time

C02810/9

0 μs

TPM (motor encoder): Delay time

C02810/10

0 μs

TPL (pos. encoder): Delay time

Read access  Write access  CINH  PLC STOP  No transfer