LS_DriveInterface - device interface

The LS_DriveInterface system block provides the internal interfaces for the device interface

in the function block editor.

Inputs

Identifier

Data type

Information/possible settings

DI_bSetCInh

BOOL

Set/reset controller inhibit

• The controller can be inhibited by different sources, e.g. via the digital input RFR

or using the device command "

Inhibit controller

".

( 55)

• The bit code under

C00158

shows the source that inhibited the controller.

TRUE Set controller inhibit.

• The power output stages in the regenerative power supply

module for regenerative feedback operation are inhibited.

• The supply in the DC bus is not affected by this "controller

inhibit".

TRUEFALSE Reset controller inhibit.

• Please note that the regenerative power supply module will only

be enabled if all sources for controller inhibit are reset!

DI_bResetError1

BOOL

DI_bResetError2

BOOL

DI_bResetError3

BOOL

Reset (acknowledge) error message

• This function resets a pending error message if the cause of the error message

has been eliminated.

• The three inputs are linked via a logic OR gate.

TRUE Reset (acknowledge) error message.

DI_bSetExternError

BOOL

Activation of error message "External error".

TRUE Activate error message with the response selected in

C00581

.

DI_bSwitchOn

BOOL

Deactivate switch-on inhibit

• If the automatic restart is inhibited (

C00142

= "0"), the state machine remains in

the "Device is ready to switch on" state after mains switching.

State "Device is ready to switch on" ( 81)

FALSETRUE The switch-on inhibit is deactivated and the regenerative power

supply module changes to the "Device is switched on" state.

LS_DriveInterface

DI_dnState

DI_bSetCInh

DI_bResetError1

DI_bSetExternError

DI_bSwitchOn

DI_bReadyToSwitchOn

DI_bReady

DI_bFailActive

DI_bImpActive

DI_bCInhActive

DI_bUVDetected

DI_bMainSupplyOk

DI_bWarningActive

DI_bOVDetected

DI_bOperationEnabled

³ 1

DI_bResetError2

DI_bResetError3

DI_dwErrorCode

DI_AxisData

Advertising