4 cause & possible remedies, Logbook: overflow [0x00650000, Logbook: reset (read error) [0x00650001 – Lenze E94ARNE Regenerative power supply User Manual

Page 209: Logbook: reset (version error) [0x00650002, Memory module is missing [0x00650003, Control card is defect [0x00680000, Cause & possible remedies, Error message in the chapter, Cause & possible, Remedies

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

209

9400 regenerative power supply module | Parameter setting

Diagnostics & fault analysis

Error messages

8.6.4

Cause & possible remedies

This chapter contains all error messages of the device operating system in numerical order

of the error number with detailed information on the response to the error message and

information on the cause & possible remedies.

Tip!
A list of all error messages of the device operating system in alphabetical order can

be found in the previous chapter "

Short overview (A-Z)

".

( 203)

Logbook: Overflow [0x00650000]

Logbook: Reset (read error) [0x00650001]

Logbook: Reset (version error) [0x00650002]

Memory module is missing [0x00650003]

Control card is defect [0x00680000]

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Too many events/errors have occurred in a very short

time. It was therefore not possible to list all of them in

the logbook.

Check whether application generates too many error

messages.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The logbook has been reset due to a read error.

- (Is irreversible)

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The logbook has been reset due to a version conflict.

- (Is irreversible)

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Memory module is defective or not available.

Use a different memory module.

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the control card.

Mains switching

• Please contact Lenze if the error occurs again.